WATERAX BB-4 Kubota Diesel

BEFORE PURCHASE PLEASE EMAIL WEBORDERS@HEIMANFIRE.COM OR CALL 605.543.6212 TO GET A SHIPPING QUOTE. ONLINE CHECKOUT DOES NOT CALCULATE CORRECT SHIPPING RATES. 

The BB-4® diesel high-pressure fire pump pairs the proven WATERAX 4-stage high pressure pump end with a powerful Kubota D902 25 HP diesel engine. Compatible with type 4, type 5, type 6 brush trucks and listed on the USFS type 6 Fire Apparatus specifications, the diesel BB-4® pump is suited to operate in a variety of fire operations. This unit is optimal for direct attack, remote watering, sprinkler systems and is popular for slip-on units. 

This unit is available in different configurations:

  • Horizontal and vertical drive orientations

Vertical is standard, if horizontal is preferred please contact 605.543.6212

    MAXIMUM PRESSURE 395 PSI
    MAXIMUM FLOW 106 US GPM
    MAXIMUM HEAD 911'

    106 GPM (401 lpm) @ 150 PSI (10.3 BAR)
    103 GPM (390 lpm) @ 250 PSI (17.2 BAR)
    65 GPM (246 lpm) @ 350 PSI (24.1 BAR)


    ENGINE:

    Model: Kubota D903-E4B, 3-Cylinder Fuel Injected Liquid Cooled Diesel 

    Starting System: 12 VDC, 1.0 kW Starter (with glow plug)

    PUMP END:

    Type: Detachable 4-stage centrifugal pump

    Intake: 2" Male NPSH

    Discharge: 1.5" Male NPSH

    WEIGHT:

    280 lbs.

    OTHER SPECS:

    Primer: Electric Primer (sold separately), click here

    Muffler: Rain Cap (standard) / Forestry Spark Arrestor (sold separately)

    Fastwire: 3' CTRL cable with 14 pin connector (standard)

    Control Options:

    PMSCP- Diesel (sold separately), click here

    Push Button On/Off Switch (lit when on), Low Pressure Protection Switch (lit when on), Push Button Engine Start, Glow Plug Timer, Low Oil Pressure, Warning Light, High Water Temperature Warning Light, Vernier Throttle, Pump Discharge Pressure Gage and mounting for optional electric primer momentary control toggle  switch (comes in electric primer kit).

    G1 Panel (sold separately), click here

    Rotary OFF/RUN/Start Switch; LED Indicators for glow plug preheat, alternator charge failure, low oil pressure, and high engine temperature. Tachometer, Hour meter, and low oil pressure and high engine temperature shut down. 

    Dual Controls (sold separately), click here

    Two individual panels each having a rotary OFF/RUN/Start Switch; LED Indicators for glow plug preheat, alternator charge failure, low oil pressure, and high engine temperature. Tachometer, Hour meter, and low oil pressure and high engine temperature shut down meter.